Model: CRX-60
Model: CRX-60
Range: 400-700nm
Function: Can quickly and accurately measure the color of an object's surface through non-contact methods, without contaminating or damaging the sample; It can also be installed on assembly lines and robotic arms.
Caliber: Φ8mm/Φ21mm
Measurement Stability: dE*ab≤0.1
Support APP: No
Support PC Software: No
Toepassingsgebieden: Het kan worden geïnstalleerd op assemblagelijnen en robotachtige armen om de kleur van producten in realtime te controleren, gegevens terug te verzenden en tijdige feedback van productkwaliteit te geven.
Maat: 230x160x150mm
Weight: 2.7kg
Verkoopeenheden: | Piece/Pieces |
The file is encrypted. Please fill in the following information to continue accessing it
Non-contact spectrofotometer is een zeer nauwkeurige kleurmetingsinstrument, dat de kleur van het oppervlak van het object snel en nauwkeurig op een vrijblijvende manier kan meten, zonder vervuiling of schade aan het monster; Het kan ook worden geïnstalleerd op de assemblagelijn en mechanische arm om de kleur van het product in realtime te controleren, de gegevens te retourneren en tijdige feedback te geven over de kwaliteit van het product.
Productkenmerken Meerdere kleurindicatoren kunnen worden gemeten
*Waterdicht en stofveilig, beveiligingsklasse IP66
*Wordt standaard geleverd met krachtige software voor pc -gegevensbeheer
*Gebruik LED -lichtbron voor een langere levensduur
*Ondersteuning van de interne kalibratie om stabiliteit met een hoge instrument te garanderen
*De methode voor kleurmeting met spectroscopie met dubbele lichtpad heeft de voordelen van hoge snelheid, hoge precisie en goede herhaalbaarheid
*Ondersteuning RS232, RS485, USB, Netwerkpoort, analoog signaal een verscheidenheid aan communicatiemodi
Model | CRX-60 |
Geometry | 45/0 |
Repeatability | dE*ab≤0.1 |
Inter-instrument agreement | / |
Display accuracy | 0.01 |
Measuring/Lighting calibers | Φ8mm/Φ21mm |
Measurement index | CIE-Lab,XYZ |
Light source condition | A,C,D65 |
Lighting source | Full band balancedLED light source |
Field angle | 2°,10° |
Meet a criterion | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Spectroscopic method | Nanobeam splitting device |
SenSor | Silicon optical array device |
Wavelength interval | 10nm |
Wavelength coverage | 400-700nm |
Reflectance measurement range | 0-200% |
Reflectance resolution | 0.01% |
Measurement and observation mode | Visual |
Calibration | Intelligent automatic calibration |
Accuracy guarantee | Ensure the first level of measurement |
Measuring time | Single measurement 110ms |
Measuring interval | 1s |
Port | USB,485,232,External trigger, analog output, Ethernet |
Screen | No |
Light source lifetime | 1 million times in 10 years |
Language | / |
Non-contact distance | 5mm |